RPC bulk-get
This RPC provides multiple get operations on multiple nodes, paths and contents. It is possible to get data from 'Operational' datastore of UniConfig topology if no content is specified, otherwise data is retrieved from the device directly (over mount-point). Operation is executed over actual/existing UniConfig transaction (immediate-commit model / manual user transaction). Each GET operation is executed in parallel. For mount-point read, it is enough to have node installed on southbound topology (if multiple mount-points with the same node-id exist, user need to specify also connection-type) or just stored in uniconfig database.
RPC input contains a list of node inputs where each consists of mandatory fields such as node-id
(UniConfig node identifier) and
path
, which points to specific subtree. Optional fields are content
, connection-type
and ignore-missing-data-error
. Content determines that the call will be
over mount-point to target device datastore config, operational, state, all
, where state, all
are only for gnmi node.
Connection type is needed only in a scenario where multiple southbound mount-points are defined with the same node-id
.
If data-missing error is not wanted, user may add ignore-missing-data-error
and set it to true (default is false) which will display empty config in data
leaf.
If get operation on any nodes failed (node is not installed, connection lost, data is not present, ...) the response
will display only failed nodes in common RFC8040 errors container. In a success case, the result is structured in
node-results format. Each node-result consists of node-id
, content
(if over mount-point) path
and
data
that contains wanted subtree config.
#
RPC examples
#
Successful example
RPC input contains valid nodes that are installed in UniConfig topology. Bulk-get will read config on following paths from UniConfig operational datastore.
curl --location --request POST 'http://localhost:8181/rests/operations/uniconfig-manager:bulk-get' \
--header 'Accept: application/json' \
--header 'Content-Type: application/json' \
--data-raw '{
"input": {
"nodes": [
{
"node-id": "R1",
"path": "frinx-openconfig-interfaces:interfaces/interface"
},
{
"node-id": "R2",
"path": "Cisco-IOS-XR-ifmgr-cfg:interface-configurations/interface-configuration"
}
]
}
}'
{
"output": {
"node-results": {
"node-result": [
{
"node-id": "R1",
"data": "{\"interface\": [{\"name\": \"GigabitEthernet0/0/0/1\", \"config\": { ... } }, ... ]}",
"path": "frinx-openconfig-interfaces:interfaces/interface"
},
{
"node-id": "R2",
"data": "{\"interface-configuration\": [{\"name\": \"GigabitEthernet0/0/0/1\", \"act\": \"active\" }, ... ]}",
"path": "Cisco-IOS-XR-ifmgr-cfg:interface-configurations/interface-configuration"
}
]
}
}
}
#
Successful example
RPC input contains valid nodes, from which Ri is installed in UniConfig topology, and R2 is installed as southbound only. Bulk-get will read config on following paths from following content target datastores.
curl --location --request POST 'http://localhost:8181/rests/operations/uniconfig-manager:bulk-get' \
--header 'Accept: application/json' \
--header 'Content-Type: application/json' \
--data-raw '{
"input": {
"nodes": [
{
"node-id": "R1",
"path": "frinx-openconfig-interfaces:interfaces/interface",
"content": "config"
},
{
"node-id": "R2",
"path": "Cisco-IOS-XR-ifmgr-cfg:interface-configurations/interface-configuration",
"content": "operational"
}
]
}
}'
{
"output": {
"node-results": {
"node-result": [
{
"node-id": "R1",
"data": "{\"interface\": [{\"name\": \"GigabitEthernet0/0/0/1\", \"config\": { ... } }, ... ]}",
"path": "frinx-openconfig-interfaces:interfaces/interface",
"content": "config"
},
{
"node-id": "R2",
"data": "{\"interface-configuration\": [{\"name\": \"GigabitEthernet0/0/0/1\", \"act\": \"active\" }, ... ]}",
"path": "Cisco-IOS-XR-ifmgr-cfg:interface-configurations/interface-configuration",
"content": "operational"
}
]
}
}
}
#
Successful example
RPC input contains two nodes, where R1 is successful and R2 does not provide any config on given path, but ignore-missing-data-error
is present.
curl --location --request POST 'http://localhost:8181/rests/operations/uniconfig-manager:bulk-get' \
--header 'Accept: application/json' \
--header 'Content-Type: application/json' \
--data-raw '{
"input": {
"nodes": [
{
"node-id": "R1",
"path": "frinx-openconfig-interfaces:interfaces/interface",
"content": "config"
},
{
"node-id": "R2",
"path": "Cisco-IOS-XR-ifmgr-cfg:interface-configurations/interface-configuration",
"content": "operational"
}
]
}
}'
{
"output": {
"node-results": {
"node-result": [
{
"node-id": "R1",
"data": "{\"interface\": [{\"name\": \"GigabitEthernet0/0/0/1\", \"config\": { ... } }, ... ]}",
"path": "frinx-openconfig-interfaces:interfaces/interface",
"content": "config"
},
{
"node-id": "R2",
"data": "{}",
"path": "Cisco-IOS-XR-ifmgr-cfg:interface-configurations/interface-configuration",
"content": "operational"
}
]
}
}
}
#
Failed example
RPC input contains valid node R1 and an invalid node R2, which is not installed in uniconfig topology and content is not specified for that node.
curl --location --request POST 'http://localhost:8181/rests/operations/uniconfig-manager:bulk-get' \
--header 'Accept: application/json' \
--header 'Content-Type: application/json' \
--data-raw '{
"input": {
"nodes": [
{
"node-id": "R1",
"path": "frinx-openconfig-interfaces:interfaces/interface"
},
{
"node-id": "R2",
"path": "Cisco-IOS-XR-ifmgr-cfg:interface-configurations/interface-configuration"
}
]
}
}'
{
"errors": {
"error": [
{
"error-tag": "data-missing",
"error-info": {
"node-id": "R2"
},
"error-message": "Node 'R2' is not installed in uniconfig topology",
"error-type": "application"
}
]
}
}
#
Failed example
RPC input contains one node with node-id R1 that has two mount-points (one is mounted over cli and the other over netconf) and no connection-type is specified.
curl --location --request POST 'http://localhost:8181/rests/operations/uniconfig-manager:bulk-get' \
--header 'Accept: application/json' \
--header 'Content-Type: application/json' \
--data-raw '{
"input": {
"nodes": [
{
"node-id": "R1",
"path": "frinx-openconfig-interfaces:interfaces/interface",
"content": "operational"
}
]
}
}'
{
"errors": {
"error": [
{
"error-tag": "protocol-conflict",
"error-info": {
"node-id": "R1",
"error": "Specify connection-type [cli, netconf, gnmi, snmp]"
},
"error-message": "Node 'R1' is installed in multiple southbound topologies 'netconf, cli'",
"error-type": "application"
}
]
}
}
#
Failed example
RPC input contains one node with node-id R3 that is not installed in uniconfig under any southbound topology.
curl --location --request POST 'http://localhost:8181/rests/operations/uniconfig-manager:bulk-get' \
--header 'Accept: application/json' \
--header 'Content-Type: application/json' \
--data-raw '{
"input": {
"nodes": [
{
"node-id": "R3",
"path": "frinx-openconfig-interfaces:interfaces/interface",
"content": "operational"
}
]
}
}'
{
"errors": {
"error": [
{
"error-tag": "data-missing",
"error-info": {
"node-id": "R3"
},
"error-message": "Node 'R3' is not installed in any southbound topology",
"error-type": "application"
}
]
}
}
#
Failed example
If RPC input does not contain any node inputs
curl --location --request POST 'http://localhost:8181/rests/operations/uniconfig-manager:is-in-sync' \
--header 'Accept: application/json' \
--header 'Content-Type: application/json' \
--data-raw '{
"input": {
"nodes": []
}
}'
{
"errors": {
"error": [
{
"error-tag": "missing-element",
"error-type": "application",
"error-message": "Input cannot be empty!"
}
]
}
}